LT-series Intelligent Variable-frequency Electric Actuator
Basic Performance Parameters
Power Supply: triphase 380VAC 50HZ,monophase 220VAC 50HZ available (only for lowtorque operation; see Selection Guide for details)
Phase Loss Protection & Automatic Phase Sequence Correcting
Protection Grade: IP68, can operate underwater at a maximum depth of 3meters for up to 48 hours
Relative Humidity: <95%
Corrosion Protection Level: C3 (C4, C5 are optional)
Ambient Temperature: -30°C~+70°C; split type installation can endure a temperature range between -30°C~+100ºC
Work System: S2/S4, etc.
Output Speed of the Electric Actuator: 7 types of speed for on-off directions
4 Command Signal Capacities for Digital Input and Output: 24VDC-10%~+30%, maximum 30mA (internal or external power)
7 Feedback Command Signal Capacities (programmable): 250VAC 6A or 30V DC 6A
Maximum Impedance of Analog Input Signal: 250Q (isolation design, with strong anti-jamming feature)
Maximum Load of Analog Feedback Signal: 750Ω (isolation design, with strong anti-jamming feature)
Intrinsic Error (Control): 1%
Repetitiveness (Control): 1%
Sensitivity (Control): 0.5%~5% adjustable
Handheld Infrared Remote Control: can be set within 0.7m wirelessly.
Expanded Performance Parameters
Output Speed Segment Setting: the speed can be independently selected within 2 intervals in the on-off directions.
Fieldbus Interface: PROFIBUS DP: support DP-V0/DP-V1/DP-V2, FF, HART.
Bluetooth Interface: achieve product setting and data upload and download by using corresponding Apps
Explosion-proof Grade: d II CT4
Operating Principles & Features
LT electric actuator is mainly composed of worm gear and worm main transmission mechanism, hermetically-sealed variable-frequency motor, manual operating assembly, output connection device, intelligent variable-frequency control unit, absolute encoder, and plug-in double sealed wiring unit. Based on current valve position signals provided by remote control room and current valve position signals transmitted from absolute encoders, the intelligent variable-frequency control unit gives commands to drive the motor by logic judgment to operate in the correct direction at a preset speed; drives the worm gear and worm main transmission mechanism; drives the output shaft; drives the valve through the output connection device; converts the changing valve position through the absolute encoder into a corresponding electrical signal and sends it to the intelligent variable-frequency control unit. When consistent with the control signal or receiving various types of protection signals, the intelligent variable-frequency control unit will cancel the drive command to stop the motor. In the event of a power failure, users can use the hand wheel to operate the worm gear through the speed planetary gear. During this process, the LT electric actuator will feed back all kinds of status signals to the remote control room.
Innovative Design
Modular design and independent installation of control units
LT electric actuators' intelligent variable-frequency control units adopt highly modular design, with only three PCBs - one is the power board with power variable-frequency control function to change the output speed and torque of the variable-frequency motor; one is the master control board for receiving control signals and logic processing, controlling the direction of rotation of the motor through the power board to achieve a variety of protection functions, data storage, output status signal, etc.; and the last one is the display panel equipped with display screen and status lights. The three PCBs are installed on different faces of the control cabinet, are field-replaceable and do not interfere with each other. (Patent No.: ZL 2015 3 0212216.X)
A variety of open-free settings
The LT electric actuator not only can be operated by pressing buttons on the on-site
operator station, but also can achieve on-site electric operation, menu commissioning, data access by using an infrared remote control (set distance less than 0.7 m), which is very important to field applications.
Bluetooth interface, to achieve communication with mobile phones (Extended Options)
The on-site operator station is equipped with a Bluetooth interface, allowing users to download our proprietary applications from LT website to achieve on-site electric operation, menu commissioning, data upload and download of LT electric actuators.
Manual speed increasing gear
The Manual operation on the speed planetary gear to drive the worm gear and worm main transmission mechanism not only solves the problem of overwhelming force needed for direct loading of output shaft by hand wheel and difficulties in rotating the hand wheel, but also tackles the headaches of large transmission ratio and long time-consumption during the use of hand wheel to drive the worm gear directly.
Big color LCD
The on-site operator station of the LT electric actuator is equipped with a 3.2" big color LCD with a resolution of 320x240, which can display the commissioning menu and all kinds of data, and is able to maintain excellent display performance even at low temperatures, with backlight intensity adjustable on site.
An emergency battery included (optional)
A storage space is specially designed for an emergency battery on the top of the cabinet cover of the control unit assembly of LT electric actuators. The battery has a high capacity of 2000mAH and is used to supply power to the display screen in the event of a power failure, allowing users to check the location of the valve and the isolation between the storage space and electrical space and helping to maintain the isolation between the electrical space and external space.
Plug-in Double Sealed Wiring Unit
The wiring unit adopts full plug-in patchboard design with reference to the connection mode of printed circuit board connector to ingeniously combine the socket and the patchboard as a whole inside the control cabinet. Users only need to complete one-time connection between the external cable and the plug during the initial installation, and there are no disconnection and connection jobs during post-maintenance. Rubber sheet is used as a separator between the patch board and the control cabinet to completely isolate the wiring space and the electrical space of this product, which ensures that the electrical space is isolated from the outside space even if the hole for external cable is not sealed due to negligence. (Patent No.: ZL 2015 2 0439993.2)
Externally connected with 24 VDC to achieve local setting and data access
LT electric actuators is equipped with an external 24 VDC terminals, which can connect 24 VDC temporary power supply externally for data access and parameter setting when power supply is not available on site.
Absolute Encoder
A 20-bit magnetic multi-turn absolute encoder is used to achieve measure range of 2-1350 circles of the electric actuator with high precision level. Each mechanical position has an unique corresponding code. In the event of a power failure, this correspondence will not be lost, and no battery support is needed. (Patent No.: ZL 2015 2 0440521.9)
Separated Installation
In case the ambient temperature is too high, or there is excessive vibration or when commissioning is impossible on site, the intelligent variable-frequency control unit and this product can be installed separately. A full set of installation assemblies and waterproof connection cables are available. Separated installation is extremely simple, helping to solve the above problems without affecting the overall performance of the actuator.
Variable-frequency Control
LT intelligent variable-frequency electric actuator adopt intelligent variable-frequency control technology -the combination of intelligent control and frequency conversion. The built-in power board (converter) will convert the power supply with fixed voltage and frequency to power supply with adjustable voltage and frequency, to achieve adjustable output torque and speed of the motor for the purpose of controlling them. Compared with traditional electric actuators, intelligent control offers the following advantages for the product.
Electric actuator selection is difficult due to different on-site conditions; in particular, the choice of output speed does not necessarily match the actual working conditions. LT electric actuator has 7types of speed both for on-off directions and ESD control to choose from on-site to achieve optimal control process.
When near or away from the fully-open or fully-closed position, LT intelligent variable-frequency electric actuator will automatically operate at a default low speed, which can avoid the impact of inertia on the valves and drive them smoothly when valve is fully- open or fully- closed.
For the control types, LT Intelligent variable-frequency electric actuator will also automatically operate at a default low speed when the control signal is close to the feedback signal to precisely locate the valve.
For LT intelligent variable-frequency electric actuator, products running at different types of segementation speed can be provided, i.e. two intervals can be set in the on-off direction for the user to select different types of running speed independently (within 7 types), so as to meet the requirement of a small number of segmentation control pipelines for flow change speed conditions. (Extended options)
When controlling the full valve travel, the motor start-up and running current of LT Intelligent variable-frequency electric actuator will never exceed the rated current of the motor, which helps to prevent it from burning out due to overheating.
The motor of LT Intelligent variable-frequency electric actuator will automatically operate at a preset low speed without affecting the its driving force on the valves. In the event of jam faults, the motor will automatically raise the operating voltage and increase the output torque without affecting the output speed.
Each specification of LT Intelligent variable-frequency electric actuator are only equipped with two speeds variable-frequency motors, to achieve a wide range of different rotational speed output, effectively reducing the inventory level of motor spare parts.
In addition to achieving control on output torque and speed, frequency conversion technology also helps to realize the following functions of LT Intelligent variable-frequency electric actuator:
Power phase sequence will not affect the motor running direction, and power phase loss will not burn the motor.
The motor stator coil temperature can be monitored continuously to achieve overheating protection of the motor.
The motor relevant parameters can be monitored continuously to achieve over-torque protection of the electric actuator.
Self-diagnosis
LT electric actuator is equipped with full fault self-diagnosis functions as follows:
Hardware faults
Software faults
Sensor faults
Motor overheating
Control unit faults
All faults are savedin chronological order in a fault log (10 faults) for easy maintenance.
Valves/ Travel Torque Characteristic Curve
LT electric actuator has the function of recording the travel torque characteristic curve, and the saved characteristic curve can provide reference for valve maintenance.
Fail-safe
In the event of a loss of external signals or bus communication failure, LT electric actuator will operate in a default fail-safe position.
ESD Protection (ESD)
The ESDprotection function can override on-site protection, forbidden protection, interlock protection and motor temperature protection to operate in the default full-on or full-off direction.
ESD emergency operating speed can be set individually. (Extended Options)
Control Interface
LT electric actuator is connected to the remote control room through analog, digital input and output. 4 contact input/output command signals and 7 contact input/output feedback signals can be programmed to give different types of content and provide optional normally open/closed status.
Signal Preservation
LT electric actuator provides the option of allowing the contact input/output feedback signals to maintain the previous state before power failure. (Extended options)
Data Management
LT electric actuator provides comprehensive management on product identity data, on-site operation data and commissioning menu. On-site operator stations, mobile phones or computers can be used on-site to do reading, editing and setting jobs.
Basic Settings
LT Electric Actuators provide basic settings, including travel position, protection value of the torque, operating speed, valve closing direction, and valve closing mode, etc. Generally, on-site routine commissioning can be done through basic settings, including valve opening settings, valve closing settings, travel settings
System Settings
The main function of the system of LT electric actuators is to set the motor model, split of control unit and other important parameters affecting the performance of the whole machine. System settings and function settings need a special code and requires professional staff to do the setting, including motor model, speed range, rated torque , power supply
Advanced Settings
When on-site operating conditions are not in line with the factory standard settings, the following parameters of LT electric actuator will be reset through advanced settings. These parameters come in series of options and basically cover the various special requirements that may exist in on-site conditions. These settings must be done by entering codes, or by restoring the factory settings. Including:
Remote control instruction mode
Local control mode
Monitoring function
Display unit
End control
ESD function
Relay output
Analog calibration
Reset to defaults
Optional Field bus PROFIBUS_DP single channel/redundant (dual channel), and support DPV0/DPV1/DPV2 protocols.
LT electric actuator can choose single channel or slave redundancy (dual channel) PROFIBUS_DP interface board for PROFIBUS Field bus connection. PROFIBUS_DP board adopts specialized PROFIBUS_DP protocol processor (ASIC/VPC3++) and electrically isolated RS485 interface to transmit data; bus interface board and core processor of the actuator's motherboard are connected with each other and exchange data through CAN bus; core processor of the motherboard provides bus interface board required data and parameters; data and parameters required for bus connection can be set via core processor of the motherboard, such as bus address and redundancy mode.
For slave redundancy interface board, each PROFIBUS_DP channel has independent ASIC and corresponding bus transmission isolated channel. The bus address of these two channels can be set from 2 to 126 independently. Independent communications can transmit data to two master stations simultaneously; and provide reliable high-speed data exchange protection for the communications between the system and the actuator.
It also supports non cyclical DP-V1 services and allows parameter settings, reading of collected data, diagnostic information and data files through bus.
DP-V2 mainly supports clock synchronization or time stamp and slave redundancy functions conforming to protocol requirements.
Control system integration
Required GSD, EDD and FDT/DTM files can be provided for different system integration.
Main Features
1.Status self-diagnosis function: primary display of the actuator has intuitive icons, showing different status of the bus for fast identification of bus faults.
2. DPVO messages: no need to use professional bus detection tools and equipment; the local operation display of the actuator is for bus communication massages query and system integration performance checking.
3. Simulation function: no need to change control system settings; users can simulate bus functions of other actuators through simple parameter settings. It provides great convenience for spare parts management and machine modification.
Basic Performance Parameters
Power Supply: triphase 380VAC 50HZ,monophase 220VAC 50HZ available (only for lowtorque operation; see Selection Guide for details)
Phase Loss Protection & Automatic Phase Sequence Correcting
Protection Grade: IP68, can operate underwater at a maximum depth of 3meters for up to 48 hours
Relative Humidity: <95%
Corrosion Protection Level: C3 (C4, C5 are optional)
Ambient Temperature: -30°C~+70°C; split type installation can endure a temperature range between -30°C~+100ºC
Work System: S2/S4, etc.
Output Speed of the Electric Actuator: 7 types of speed for on-off directions
4 Command Signal Capacities for Digital Input and Output: 24VDC-10%~+30%, maximum 30mA (internal or external power)
7 Feedback Command Signal Capacities (programmable): 250VAC 6A or 30V DC 6A
Maximum Impedance of Analog Input Signal: 250Q (isolation design, with strong anti-jamming feature)
Maximum Load of Analog Feedback Signal: 750Ω (isolation design, with strong anti-jamming feature)
Intrinsic Error (Control): 1%
Repetitiveness (Control): 1%
Sensitivity (Control): 0.5%~5% adjustable
Handheld Infrared Remote Control: can be set within 0.7m wirelessly.
Expanded Performance Parameters
Output Speed Segment Setting: the speed can be independently selected within 2 intervals in the on-off directions.
Fieldbus Interface: PROFIBUS DP: support DP-V0/DP-V1/DP-V2, FF, HART.
Bluetooth Interface: achieve product setting and data upload and download by using corresponding Apps
Explosion-proof Grade: d II CT4
Operating Principles & Features
LT electric actuator is mainly composed of worm gear and worm main transmission mechanism, hermetically-sealed variable-frequency motor, manual operating assembly, output connection device, intelligent variable-frequency control unit, absolute encoder, and plug-in double sealed wiring unit. Based on current valve position signals provided by remote control room and current valve position signals transmitted from absolute encoders, the intelligent variable-frequency control unit gives commands to drive the motor by logic judgment to operate in the correct direction at a preset speed; drives the worm gear and worm main transmission mechanism; drives the output shaft; drives the valve through the output connection device; converts the changing valve position through the absolute encoder into a corresponding electrical signal and sends it to the intelligent variable-frequency control unit. When consistent with the control signal or receiving various types of protection signals, the intelligent variable-frequency control unit will cancel the drive command to stop the motor. In the event of a power failure, users can use the hand wheel to operate the worm gear through the speed planetary gear. During this process, the LT electric actuator will feed back all kinds of status signals to the remote control room.
Innovative Design
Modular design and independent installation of control units
LT electric actuators' intelligent variable-frequency control units adopt highly modular design, with only three PCBs - one is the power board with power variable-frequency control function to change the output speed and torque of the variable-frequency motor; one is the master control board for receiving control signals and logic processing, controlling the direction of rotation of the motor through the power board to achieve a variety of protection functions, data storage, output status signal, etc.; and the last one is the display panel equipped with display screen and status lights. The three PCBs are installed on different faces of the control cabinet, are field-replaceable and do not interfere with each other. (Patent No.: ZL 2015 3 0212216.X)
A variety of open-free settings
The LT electric actuator not only can be operated by pressing buttons on the on-site
operator station, but also can achieve on-site electric operation, menu commissioning, data access by using an infrared remote control (set distance less than 0.7 m), which is very important to field applications.
Bluetooth interface, to achieve communication with mobile phones (Extended Options)
The on-site operator station is equipped with a Bluetooth interface, allowing users to download our proprietary applications from LT website to achieve on-site electric operation, menu commissioning, data upload and download of LT electric actuators.
Manual speed increasing gear
The Manual operation on the speed planetary gear to drive the worm gear and worm main transmission mechanism not only solves the problem of overwhelming force needed for direct loading of output shaft by hand wheel and difficulties in rotating the hand wheel, but also tackles the headaches of large transmission ratio and long time-consumption during the use of hand wheel to drive the worm gear directly.
Big color LCD
The on-site operator station of the LT electric actuator is equipped with a 3.2" big color LCD with a resolution of 320x240, which can display the commissioning menu and all kinds of data, and is able to maintain excellent display performance even at low temperatures, with backlight intensity adjustable on site.
An emergency battery included (optional)
A storage space is specially designed for an emergency battery on the top of the cabinet cover of the control unit assembly of LT electric actuators. The battery has a high capacity of 2000mAH and is used to supply power to the display screen in the event of a power failure, allowing users to check the location of the valve and the isolation between the storage space and electrical space and helping to maintain the isolation between the electrical space and external space.
Plug-in Double Sealed Wiring Unit
The wiring unit adopts full plug-in patchboard design with reference to the connection mode of printed circuit board connector to ingeniously combine the socket and the patchboard as a whole inside the control cabinet. Users only need to complete one-time connection between the external cable and the plug during the initial installation, and there are no disconnection and connection jobs during post-maintenance. Rubber sheet is used as a separator between the patch board and the control cabinet to completely isolate the wiring space and the electrical space of this product, which ensures that the electrical space is isolated from the outside space even if the hole for external cable is not sealed due to negligence. (Patent No.: ZL 2015 2 0439993.2)
Externally connected with 24 VDC to achieve local setting and data access
LT electric actuators is equipped with an external 24 VDC terminals, which can connect 24 VDC temporary power supply externally for data access and parameter setting when power supply is not available on site.
Absolute Encoder
A 20-bit magnetic multi-turn absolute encoder is used to achieve measure range of 2-1350 circles of the electric actuator with high precision level. Each mechanical position has an unique corresponding code. In the event of a power failure, this correspondence will not be lost, and no battery support is needed. (Patent No.: ZL 2015 2 0440521.9)
Separated Installation
In case the ambient temperature is too high, or there is excessive vibration or when commissioning is impossible on site, the intelligent variable-frequency control unit and this product can be installed separately. A full set of installation assemblies and waterproof connection cables are available. Separated installation is extremely simple, helping to solve the above problems without affecting the overall performance of the actuator.
Variable-frequency Control
LT intelligent variable-frequency electric actuator adopt intelligent variable-frequency control technology -the combination of intelligent control and frequency conversion. The built-in power board (converter) will convert the power supply with fixed voltage and frequency to power supply with adjustable voltage and frequency, to achieve adjustable output torque and speed of the motor for the purpose of controlling them. Compared with traditional electric actuators, intelligent control offers the following advantages for the product.
Electric actuator selection is difficult due to different on-site conditions; in particular, the choice of output speed does not necessarily match the actual working conditions. LT electric actuator has 7types of speed both for on-off directions and ESD control to choose from on-site to achieve optimal control process.
When near or away from the fully-open or fully-closed position, LT intelligent variable-frequency electric actuator will automatically operate at a default low speed, which can avoid the impact of inertia on the valves and drive them smoothly when valve is fully- open or fully- closed.
For the control types, LT Intelligent variable-frequency electric actuator will also automatically operate at a default low speed when the control signal is close to the feedback signal to precisely locate the valve.
For LT intelligent variable-frequency electric actuator, products running at different types of segementation speed can be provided, i.e. two intervals can be set in the on-off direction for the user to select different types of running speed independently (within 7 types), so as to meet the requirement of a small number of segmentation control pipelines for flow change speed conditions. (Extended options)
When controlling the full valve travel, the motor start-up and running current of LT Intelligent variable-frequency electric actuator will never exceed the rated current of the motor, which helps to prevent it from burning out due to overheating.
The motor of LT Intelligent variable-frequency electric actuator will automatically operate at a preset low speed without affecting the its driving force on the valves. In the event of jam faults, the motor will automatically raise the operating voltage and increase the output torque without affecting the output speed.
Each specification of LT Intelligent variable-frequency electric actuator are only equipped with two speeds variable-frequency motors, to achieve a wide range of different rotational speed output, effectively reducing the inventory level of motor spare parts.
In addition to achieving control on output torque and speed, frequency conversion technology also helps to realize the following functions of LT Intelligent variable-frequency electric actuator:
Power phase sequence will not affect the motor running direction, and power phase loss will not burn the motor.
The motor stator coil temperature can be monitored continuously to achieve overheating protection of the motor.
The motor relevant parameters can be monitored continuously to achieve over-torque protection of the electric actuator.
Self-diagnosis
LT electric actuator is equipped with full fault self-diagnosis functions as follows:
Hardware faults
Software faults
Sensor faults
Motor overheating
Control unit faults
All faults are savedin chronological order in a fault log (10 faults) for easy maintenance.
Valves/ Travel Torque Characteristic Curve
LT electric actuator has the function of recording the travel torque characteristic curve, and the saved characteristic curve can provide reference for valve maintenance.
Fail-safe
In the event of a loss of external signals or bus communication failure, LT electric actuator will operate in a default fail-safe position.
ESD Protection (ESD)
The ESDprotection function can override on-site protection, forbidden protection, interlock protection and motor temperature protection to operate in the default full-on or full-off direction.
ESD emergency operating speed can be set individually. (Extended Options)
Control Interface
LT electric actuator is connected to the remote control room through analog, digital input and output. 4 contact input/output command signals and 7 contact input/output feedback signals can be programmed to give different types of content and provide optional normally open/closed status.
Signal Preservation
LT electric actuator provides the option of allowing the contact input/output feedback signals to maintain the previous state before power failure. (Extended options)
Data Management
LT electric actuator provides comprehensive management on product identity data, on-site operation data and commissioning menu. On-site operator stations, mobile phones or computers can be used on-site to do reading, editing and setting jobs.
Basic Settings
LT Electric Actuators provide basic settings, including travel position, protection value of the torque, operating speed, valve closing direction, and valve closing mode, etc. Generally, on-site routine commissioning can be done through basic settings, including valve opening settings, valve closing settings, travel settings
System Settings
The main function of the system of LT electric actuators is to set the motor model, split of control unit and other important parameters affecting the performance of the whole machine. System settings and function settings need a special code and requires professional staff to do the setting, including motor model, speed range, rated torque , power supply
Advanced Settings
When on-site operating conditions are not in line with the factory standard settings, the following parameters of LT electric actuator will be reset through advanced settings. These parameters come in series of options and basically cover the various special requirements that may exist in on-site conditions. These settings must be done by entering codes, or by restoring the factory settings. Including:
Remote control instruction mode
Local control mode
Monitoring function
Display unit
End control
ESD function
Relay output
Analog calibration
Reset to defaults
Optional Field bus PROFIBUS_DP single channel/redundant (dual channel), and support DPV0/DPV1/DPV2 protocols.
LT electric actuator can choose single channel or slave redundancy (dual channel) PROFIBUS_DP interface board for PROFIBUS Field bus connection. PROFIBUS_DP board adopts specialized PROFIBUS_DP protocol processor (ASIC/VPC3++) and electrically isolated RS485 interface to transmit data; bus interface board and core processor of the actuator's motherboard are connected with each other and exchange data through CAN bus; core processor of the motherboard provides bus interface board required data and parameters; data and parameters required for bus connection can be set via core processor of the motherboard, such as bus address and redundancy mode.
For slave redundancy interface board, each PROFIBUS_DP channel has independent ASIC and corresponding bus transmission isolated channel. The bus address of these two channels can be set from 2 to 126 independently. Independent communications can transmit data to two master stations simultaneously; and provide reliable high-speed data exchange protection for the communications between the system and the actuator.
It also supports non cyclical DP-V1 services and allows parameter settings, reading of collected data, diagnostic information and data files through bus.
DP-V2 mainly supports clock synchronization or time stamp and slave redundancy functions conforming to protocol requirements.
Control system integration
Required GSD, EDD and FDT/DTM files can be provided for different system integration.
Main Features
1.Status self-diagnosis function: primary display of the actuator has intuitive icons, showing different status of the bus for fast identification of bus faults.
2. DPVO messages: no need to use professional bus detection tools and equipment; the local operation display of the actuator is for bus communication massages query and system integration performance checking.
3. Simulation function: no need to change control system settings; users can simulate bus functions of other actuators through simple parameter settings. It provides great convenience for spare parts management and machine modification.
Address:
No. 19 Xinxing Road, Dianshanhu District, Kunshan, Jiansu Province. / No.123 Jiuye Road, Qingpu District, Shanghai
Business Type:
Manufacturer/Factory
Business Range:
Chemicals, Construction & Decoration, Electrical & Electronics, Industrial Equipment & Components, Light Industry & Daily Use, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Main Products:
Acuator
Company Introduction:
After connected to various types of valves, the electric actuator receives remote control signals and transmits local signals remotely to the control center. Through precision control on the valve travel and reliable protection on the torque, and perfect self fault-diagnosis function, it achieves safety regulation of the pipeline medium flow and meets users′ higher expectations on the technological level, thereby, hundreds of thousands of our products being widely used in the fields of Power, Gas and Oil, Chemical Processing, Water Treatment, Mining, Metallurgy, Ship Building, Pulp and Paper, Municipal, Environmental, etc.
The company has a total investment of nearly 100 million RMB. With large investment and high starting point, various types of equipment are equipped during R& D and production process to meet high standards of product development, parts manufacturing, component assembly, appearance processing, process testing, etc.
The company accumulates more than 20 years of field experience and fully draws on advanced and innovative technologies of similar products at home and abroad without any simple imitation. The company philosophy is "I possess what others lack; I outperform other competitors".
LT electric actuator is an independent brand product with completely independent intellectual property rights. The registered trademark LT consists of first letters and Chinese characters of "Limit-Limit travel control" and "Torque-Torque protection". The logo implies a lever: With a fulcrum, LT electric actuator can move towards the world.
Our LT-series electric actuators are technologically advanced, beautifully designed, simple installation, easy operation, distinctive features for field use, and a number of patented technologies.
The company has a total investment of nearly 100 million RMB. With large investment and high starting point, various types of equipment are equipped during R& D and production process to meet high standards of product development, parts manufacturing, component assembly, appearance processing, process testing, etc.
The company accumulates more than 20 years of field experience and fully draws on advanced and innovative technologies of similar products at home and abroad without any simple imitation. The company philosophy is "I possess what others lack; I outperform other competitors".
LT electric actuator is an independent brand product with completely independent intellectual property rights. The registered trademark LT consists of first letters and Chinese characters of "Limit-Limit travel control" and "Torque-Torque protection". The logo implies a lever: With a fulcrum, LT electric actuator can move towards the world.
Our LT-series electric actuators are technologically advanced, beautifully designed, simple installation, easy operation, distinctive features for field use, and a number of patented technologies.
Send your message to this supplier